IBM-80H Electro-Hydraulic Hybrid-Servo Injection Blow Molding Machine
The LIANXIN IBM-80H is a electro-hydraulic hybrid-servo injection blow molding machine for hybrid-servo projects needing a larger 730 cm³ catalogue injection volume and up to 120 mm product diameter. Model selection must be confirmed from the bottle, resin, mould, cavities, target output and site utilities—not from model name alone.
Catalogue reference specifications
| Parameter | Catalogue reference |
|---|---:|
| Screw diameter | 60 mm |
| Screw L/D | 21 |
| Maximum injection volume | 730 cm³ |
| HDPE reference injection capacity | 510 g |
| Injection pressure | 135 MPa |
| Injection clamping force | 960 kN |
| Blow clamping force | 133 kN |
| Catalogue product-volume range | 0.015–1 L |
| Maximum product height | 275 mm |
| Maximum product diameter | 120 mm |
| Machine dimensions | 5.7 × 2.35 × 2.3 m |
| Machine weight | 9.8 t |
These figures are catalogue references, not a guaranteed production output. Final values and acceptance criteria belong in the controlled project specification.
Where IBM-80H fits in the series
The IBM-H option to review when the mould, shot requirement or bottle diameter is beyond IBM-50H but the project remains within the published 1 L product range.
Use the IBM-H family comparison to compare all published models before confirming a machine.
Materials and bottle review
Catalogue project materials for this family may include HDPE, LDPE, PE, PP, PS and EVA. Suitability depends on the approved resin grade, bottle geometry, neck finish, wall distribution, mould, cycle and required inspection. A published volume range does not confirm every bottle shape within that range.
Certification and evidence boundary
The customer-supplied UDEM CE evidence includes IBM-80H. Qualification work should still use the current controlled copy and the exact purchased configuration.
Information LIANXIN needs before configuration
- Bottle drawing or physical sample
- Approved resin grade
- Bottle volume, weight, height, diameter and neck finish
- Cavity plan and target output
- Appearance, wall-distribution, leak and closure criteria
- Site voltage, cooling water, compressed air and available space
- Required inspection, documentation and market qualification
Questions about IBM-80H
What bottle size can IBM-80H make?
The catalogue reference is 0.015–1 L, with a maximum product height of 275 mm and maximum product diameter of 120 mm. The actual bottle must be reviewed with its resin and mould.
Does the catalogue dry-cycle or capacity value guarantee output?
No. Output depends on bottle weight and geometry, resin, cavities, cooling, utilities, mould design, settings and acceptance criteria. A guaranteed output requires an agreed bottle trial and written acceptance method.
What should be compared before moving to another model?
Compare injection volume, reference injection capacity, clamping force, product envelope, mould arrangement, machine footprint and utilities—not bottle volume alone.
Review IBM-H machines, compare IBM-H and IBM-E or send a bottle drawing.